The "FI Link sanity checks" message reports a transient hardware issue.
When a "FI Link sanity checks" event occurs, a message similar to the following is reported:
Jan 22 175942 router0 %PFE-3 fpc0 XMCHIP(2)XMCHIP(2) FI Link sanity checks - Type 4 Seq Number 1983 Stream 7 Link0 0x80 Link1 0x60 Link2 0x8001
This issue may be caused by hardware transient errors. A complete software workaround or fix is not available. Enhancements have been added in PR1264656 and PR1262868 to check the combination of Link Sanity checks interrupt and cell underflow events and verify there is true operational impact to report a new event, such as the following syslog entries.
FI: Link sanity check and high rate cell underflow errors
FI: Cell underflow errors with reorder engine pointers stalled
{DIDYOUKNOWSERVICENOWTOKEN.EN_US} Perform these steps to determine the cause and resolve the problem (if any). Continue through each step until the problem is resolved.
Collect the show command output.
Capture the output to a file (in case you have to open a technical support case). To do this, configure each SSH client/terminal emulator to log your session.
show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit
Analyze the show command output.
In the 'show log messages', review the events that occurred at or just before the appearance of the "FI Link sanity checks" message. Frequently these events help identify the cause.
This article is indexed in KB31893 - Primary Index of Articles for Troubleshooting PFE ASIC Syslog Events [juniper.net] ; tag XMCHIPTSG Tip: When looking at an event in the logs, it is important to focus on the first error message in a collection of syslog messages. The first error message is usually the cause of all the follow-on error messages. The follow-on collateral damage error messages can be ignored.