The "PPE Errors lmem data error" message reports a transient hardware issue.This is a Troubleshooting Article for a PFE ASIC Syslog Event. To view other documented syslog events related to XMCHIP, XLCHIP, MQCHIP, LUCHIP, EACHIP, and PECHIP, see KB31893 - Master Index of Articles for Troubleshooting PFE ASIC Syslog Events [juniper.net] ..
When a "PPE Errors lmem data error" event occurs, a message similar to the following is reported:
Jan 19 19:17:26 router0 fpc0 LUCHIP(2) PPE_0 Errors lmem data error 0x00000c91Jan 19 19:17:26 router0 fpc0 PPE PPE HW Fault Trap: Count 1, PC 2dd, 0x02dd: flow_export_recompute_udp_checksum_for_ipv6Indications:
These memory parity errors will be automatically corrected.
Hardware PPE traps would be seen
HW Fault Trap: Count #; The amount of traffic drop can be found in the ‘count’ of the HW fault trap message
This is a transient memory parity error which may be service impacting. Repeated errors would disable the affecting zone and report a syslog event like the following:
LMEM errors require LUCHIP(2) PPE 12 Zone 2 disable
If there is a permanent impact on packet forwarding, it will be accompanied by one of the following events:
PR1152026 , PR1082932 and PR1033660 fixed lmem data error handling scenarios. {DIDYOUKNOWSERVICENOWTOKEN.EN_US}Perform these steps to determine the cause and resolve the problem (if any). Continue through each step until the problem is resolved.
Collect the show command output.
{SYSLOGSERVICENOWTOKEN.EN_US}
Capture the output to a file (in case you have to open a technical support case). To do this, configure each SSH client/terminal emulator to log your session.
show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit
Analyze the show command output.
In the 'show log messages', review the events that occurred at or just before the appearance of the "PPE Errors lmem data error" message. Frequently, these events help identify the cause.
No RMA is required
Restart FPC if permanent impact on packet forwarding is seen. Before restart, collect the debugging information using scripts KB31922 - shell script collecting data if packet forwarding at Packet Forwarding Engine is compromised [juniper.net]
Monitor this error message
Contact your technical support representative if the issue is seen after FPC restart.
This article is indexed in KB31893 - Primary Index of Articles for Troubleshooting PFE ASIC Syslog Events [juniper.net] ; tag LUCHIPTSGTip: When looking at an event in the logs, it is important to focus on the first error message in a collection of syslog messages. The first error message is usually the cause of all the follow-on error messages. The follow-on collateral damage error messages can be ignored.
2019-10-14: Article reviewed for accuracy; no changes required.