The "Parity error for CPFIFO data memory" message reports a transient hardware issue. This is a Troubleshooting Article for a PFE ASIC Syslog Event. To view other documented syslog events related to XMCHIP, XLCHIP, MQCHIP, LUCHIP, EACHIP, and PECHIP, see KB31893 - Master Index of Articles for Troubleshooting PFE ASIC Syslog Events [juniper.net] . .
When a "Parity error for CPFIFO data memory" event occurs, a message similar to the following is reported: May 3 00:43:31 router0 fpc4 XMCHIP(0):XMCHIP(0): PT0: Protect: Parity error for CPFIFO data memory 3 (0x3) Indications:
May 3 00:43:31 router0 fpc4 XMCHIP(0):XMCHIP(0): PT0: Protect: Parity error for CPFIFO data memory 3 (0x3) Indications:
The cause is due to a transient hardware issue detected in the XMCHIP CPFIFO memory.
{DIDYOUKNOWSERVICENOWTOKEN.EN_US} Perform these steps to determine the cause and resolve the problem (if any). Continue through each step until the problem is resolved.
Collect the show command output.
Capture the output to a file (in case you have to open a technical support case). To do this, configure each SSH client/terminal emulator to log your session.
show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit
clear chassis fpc errors fpc-slot <x> all
This article is indexed in KB31893 - primary Index of Articles for Troubleshooting PFE ASIC Syslog Events [juniper.net] ; tag XMCHIPTSG
Tip: When looking at an event in the logs, it is important to focus on the first error message in a collection of syslog messages. The first error message is usually the cause of all the follow-on error messages. The follow-on collateral damage error messages can be ignored.
2019-10-14: Article reviewed for accuracy; no changes required.
Note: KB Team - All changes to this article must be approved by the AI-Scripts Review team ( [email protected] ) before re-publishing.