The " Parity error for DRD memory" message reports a transient hardware error.
When a " Parity error for DRD memory" event occurs, a message similar to the following is reported: Feb 7 14:51:02 router0 fpc4 XMCHIP(0):XMCHIP(0): DRD: Protect 1: Parity error for DRD memory 7
Feb 7 14:51:02 router0 fpc4 XMCHIP(0):XMCHIP(0): DRD: Protect 1: Parity error for DRD memory 7
Indications:
The cause is due to a parity error detected in internal memory due to a transient hardware error.
{DIDYOUKNOWSERVICENOWTOKEN.EN_US} Perform these steps to determine the cause and resolve the problem (if any). Continue through each step until the problem is resolved.
Collect the show command output.
Capture the output to a file (in case you have to open a technical support case). To do this, configure each SSH client/terminal emulator to log your session.
show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit
Analyze the show command output.
In the 'show log messages', review the events that occurred at or just before the appearance of the " Parity error for DRD memory " message. Frequently these events help identify the cause.
No RMA required.
FPC restart during a maintenance window should clear this error.
With the single occurrence, the alarm can be cleared using command command, clear chassis fpc errors fpc-slot <x> all
clear chassis fpc errors fpc-slot <x> all
The multiple continuous occurrences of errors require FPC restart during maintenance window to clear the alarms.
Contact your technical support representative if the issue is seen after a FPC restart.
This article is indexed in KB31893 - Primary Index of Articles for Troubleshooting PFE ASIC Syslog Events [juniper.net] ; tag XMCHIPTSG
2019-10-14: Article reviewed for accuracy; no changes required.