The "SChunk allocation memory parity error" message reports a transient hardware error.
When a "SChunk allocation memory parity error" event occurs, a message similar to the following is reported: Feb 27 14:09:14 router0 fpc10 XMCHIP(1): MALLOC: SChunk allocation memory parity error - Address 0x77
Feb 27 14:09:14 router0 fpc10 XMCHIP(1): MALLOC: SChunk allocation memory parity error - Address 0x77
Indications:
The cause is due to a hardware parity error detected in chip memory. If there is a service impact then other events will be reported.
{DIDYOUKNOWSERVICENOWTOKEN.EN_US} Perform these steps to determine the cause and resolve the problem (if any). Continue through each step until the problem is resolved.
Collect the show command output.
Capture the output to a file (in case you have to open a technical support case). To do this, configure each SSH client/terminal emulator to log your session.
show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit
Analyze the show command output.
In the 'show log messages', review the events that occurred at or just before the appearance of the "SChunk allocation memory parity error" message. Frequently these events help identify the cause.
clear chassis fpc errors fpc-slot <x> all
This article is indexed in KB31893 - Primary Index of Articles for Troubleshooting PFE ASIC Syslog Events [juniper.net] ; tag XMCHIPTSG