The "Command sequence error" message reports a problem in the DRD (Dispatch and Reorder Block) state machine.
When a "Command sequence error" event occurs, a message similar to the following is reported: Apr 3 18:43:31 re0 fpc6 XMCHIP(0):XMCHIP(0): DRD0: Command sequence error - Reorder ID 816 Sep 6 05:44:32 router0 fpc9 :XMCHIP(0): %PFE-0-DRD1: Command sequence error - Reorder ID 1443 Indications:
Apr 3 18:43:31 re0 fpc6 XMCHIP(0):XMCHIP(0): DRD0: Command sequence error - Reorder ID 816 Sep 6 05:44:32 router0 fpc9 :XMCHIP(0): %PFE-0-DRD1: Command sequence error - Reorder ID 1443
MPC fabric selfping blackhole (1) exceed raising threshold (1) occurrance (0) for module/pfe (8:3)
Host Loopback: HOST LOOPBACK WEDGE DETECTED IN PATH ID <x>
The issue is with the DRD0 block for the WAN side and the DRD1 for the fabric side. This could be caused by either hardware, transient memory event, or software. Mostly this is Software related. Review the XLCHIP/LUCHIP PPE traps, error messages, and inter-ASIC HSL2 errors to isolate the cause.
Some other PRs that could cause this: PR1082932 , PR1157173 , PR1166479 . Also, PR1067234 addressed an exposure. The following KB entries might be relevant: KB31617 - Syslog message: XMCHIP.*DRD.*Fabric parcel timeout error [juniper.net] KB31701 - Syslog message: XMCHIP.*DRD.*Wan parcel timeout error [juniper.net] KB32168 - Syslog message: HOST LOOPBACK WEDGE DETECTED [juniper.net]
{DIDYOUKNOWSERVICENOWTOKEN.EN_US} Perform these steps to determine the cause and resolve the problem (if any). Continue through each step until the problem is resolved.
Collect the show command output.
Capture the output to a file (in case you have to open a technical support case). To do this, configure each SSH client/terminal emulator to log your session.
show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit
Analyze the show command output.
In the 'show log messages', review the events that occurred at or just before the appearance of the "Command sequence error" message. Frequently these events help identify the cause. You will need to look for XL/LU PPE traps, error messages, and inter-ASIC HSL2 errors.
This article is indexed in KB31893 - Primary Index of Articles for Troubleshooting PFE ASIC Syslog Events [juniper.net] ; tag XMCHIPTSG
2019-10-14: Article reviewed for accuracy; added this symptom is mostly Software related.