This article explains the procedure for adding a new member with auto-upgrade on a QFX5100-VC. It is useful for replacing an existing member with a new RMA.
One of a 3 member VC failed. A new RMA is received with Junos 14.1X53-D30, which is different from my current Junos running on a 2 member Xqfx5100 VC 14.1X53-D35. Failure logs seen during auto-upgrade:
Jul 22 11:59:00 ch_vchassis_auto_upgrade_periodic: enabled=TRUE mixed=FALSE Jul 22 11:59:00 ch_vchassis_auto_upgrade_periodic: member 2 package /var/tmp/jinstall-qfx-5-14.1X53-D30.5-domestic-signed.tgz Jul 22 11:59:00 ch_vchassis_auto_upgrade_preparation: /var/tmp/jinstall-qfx-5-14.1X53-D30.5-domestic-signed.tgz Jul 22 11:59:00 ch_vchassis_auto_upgrade_preparation: failed Jul 22 11:59:00 ch_vchassis_auto_upgrade_periodic: failed preparation of package /var/tmp/jinstall-qfx-5-14.1X53-D30.5-domestic-signed.tgz Jul 22 11:59:00 ch_vchassis_auto_upgrade_periodic: end_upgrade: ineligible=1, role=1 Jul 22 11:59:16 (fpc_sfxpc_pfe_resync_done) : FPC 2 CM_MSG_QFX_PFE_RESYNC_DONE ch_pfem_peered: 0xf
The minimum Junos version required is 14.1X53-D30 and above.
set virtual-chassis auto-sw-update package-name /var/tmp/jinstall-qfx-5-flex-14.1X53-D35.3-domestic-signed.tgz set chassis auto-image-upgrade
set chassis auto-image-upgrade
Juniper> show virtual-chassis Virtual Chassis ID: 982e.f32b.a423 Virtual Chassis Mode: Enabled Mstr Mixed Route Neighbor List Member ID Status Serial No Model prio Role Mode Mode ID Interface 0 (FPC 0) Prsnt TA3715320519 qfx5100-48s-6q 128 Backup N VC 1 vcp-255/0/2 2 vcp-255/0/50 1 (FPC 1) Prsnt TA3715320792 qfx5100-48s-6q 128 Master* N VC 0 vcp-255/0/2 2 (FPC 2) Prsnt TA3715320132 qfx5100-48s-6q 128 Linecard N VC 0 vcp-255/0/50