This article clarifies how IP and interface monitoring values such as priority, threshold, and weights work, and describes how these values affect failover in a Chassis Cluster for SRX.
The three example cases below clarify how IP and interface monitoring values such as priority, threshold, and weights work, and describe how these values affect failover in a Chassis Cluster for SRX.
{primary:node0}[edit] root@primarynode# show | display set | match ip-mon set chassis cluster redundancy-group 1 ip-monitoring global-weight 210 <-- This value is subtracted from threshold when IP monitoring fails and weight is greater than global threshold. set chassis cluster redundancy-group 1 ip-monitoring global-threshold 110 set chassis cluster redundancy-group 1 ip-monitoring family inet 11.11.11.2 weight 120 <-- This weight should exceed "global threshold" (here 110) for IP monitor status to change. So, it makes sense to have weight greater than global-threshold when monitoring single IP. set chassis cluster redundancy-group 1 ip-monitoring family inet 11.11.11.2 interface reth1.0 secondary-ip-address 11.11.11.100 IP Monitoring status down: {primary:node0}[edit] root@primarynode# run show chassis cluster ip-monitoring status node0: -------------------------------------------------------------------------- Redundancy group: 1 IP address Status Failure count Reason 11.11.11.2 unreachable 3 unknown node1: -------------------------------------------------------------------------- Redundancy group: 1 IP address Status Failure count Reason 11.11.11.2 unreachable 4 no route to host To Check Threshold Value: {primary:node0}[edit] root@primarynode# run show chassis cluster information detail node0: -------------------------------------------------------------------------- Redundancy mode: Configured mode: active-active Operational mode: active-active Redundancy group: 0, Threshold: 255, Monitoring failures: none Events: Sep 13 15:56:04.223 : hold->secondary, reason: Hold timer expired Sep 13 15:56:59.408 : secondary->primary, reason: Control & Fabric links down Redundancy group: 1, Threshold: 45, Monitoring failures: ip-monitoring <-- Threshold is 255 when all links in reth are up, when ip-monitoring fails, global-weight defined in interface-monitoring is subtracted from threshold. Note that this threshold value is also affected by interface-monitoring status and configuration. When threshold=0, priority for node=0.
{primary:node0}[edit] root@primarynode# run show chassis cluster status Cluster ID: 10 Node Priority Status Preempt Manual failover Redundancy group: 0 , Failover count: 0 node0 200 primary no no node1 10 secondary no no Redundancy group: 1 , Failover count: 0 node0 200 primary yes no node1 10 secondary yes no
Note: In the example above, the priority is unaffected because the threshold equals 45, which is not equal to 0. As a result, failover is not triggered.
If global-weight is changed to 255, it is possible to see how ip-monitoring failure alone can affect priority on the node:
{primary:node0}[edit] root@primarynode# ...r redundancy-group 1 ip-monitoring global-weight 255 {primary:node0}[edit] root@primarynode# run show chassis cluster status Cluster ID: 10 Node Priority Status Preempt Manual failover Redundancy group: 0 , Failover count: 0 node0 200 primary no no node1 10 secondary no no Redundancy group: 1 , Failover count: 43 node0 0 primary yes no <-- This is because IP is unreachable for both the nodes as per ip-monitoring. node1 0 secondary yes no <-- This is because IP is unreachable for both the nodes as per ip-monitoring. {primary:node0}[edit] root@primarynode# run show chassis cluster ip-monitoring status node0: -------------------------------------------------------------------------- Redundancy group: 1 IP address Status Failure count Reason 11.11.11.2 unreachable 3 unknown node1: -------------------------------------------------------------------------- Redundancy group: 1 IP address Status Failure count Reason 11.11.11.2 unreachable 4 no route to host {primary:node0}[edit] root@primarynode# run show chassis cluster information detail node0: -------------------------------------------------------------------------- Redundancy mode: Configured mode: active-active Operational mode: active-active Redundancy group: 0, Threshold: 255, Monitoring failures: none Events: Sep 13 15:56:04.223 : hold->secondary, reason: Hold timer expired Sep 13 15:56:59.408 : secondary->primary, reason: Control & Fabric links down Redundancy group: 1, Threshold: 0, Monitoring failures: ip-monitoring <-- Threshold is 0, so priority in cluster changed to 0. Events: Sep 13 17:15:26.582 : secondary->primary, reason: Remote node is in secondary hol Sep 13 17:15:32.671 : primary->secondary-hold, reason: Monitor failed: IF IP Sep 13 17:15:33.683 : secondary-hold->secondary, reason: Back to back failover interval Sep 13 17:15:35.053 : secondary->primary, reason: Remote node is in secondary hol
{primary:node0}[edit] root@primarynode# show | display set | match ip-mon set chassis cluster redundancy-group 1 ip-monitoring global-weight 210 <-- Change to 210 in configuration. Before ip-monitoring failure for global-weight 210: {primary:node0}[edit] root@primarynode# run show chassis cluster status Cluster ID: 10 Node Priority Status Preempt Manual failover Redundancy group: 0 , Failover count: 0 node0 200 primary no no node1 10 secondary no no Redundancy group: 1 , Failover count: 0 node0 200 primary yes no node1 10 secondary yes no {primary:node0}[edit] root@primarynode# run show chassis cluster information detail node0: -------------------------------------------------------------------------- Redundancy mode: Configured mode: active-active Operational mode: active-active Redundancy group: 0, Threshold: 255, Monitoring failures: none Events: Sep 13 15:56:04.223 : hold->secondary, reason: Hold timer expired Sep 13 15:56:59.408 : secondary->primary, reason: Control & Fabric links down Redundancy group: 1, Threshold: 127, Monitoring failures: interface-monitoring <-- Threshold is 127 because an interface is down as per interface-monitoring. Events: Sep 13 17:15:35.053 : secondary->primary, reason: Remote node is in secondary hol Sep 13 17:15:41.268 : primary->secondary-hold, reason: Monitor failed: IF IP Sep 13 17:15:42.274 : secondary-hold->secondary, reason: Back to back failover interval Sep 13 17:17:54.614 : secondary->primary, reason: Remote node is in secondary hol ---(more)---[abort]
To check interface-monitor status:
{primary:node0}[edit] root@primarynode# run show chassis cluster interfaces Control link status: Up Control interfaces: Index Interface Status 0 fxp1 Up Fabric link status: Up Fabric interfaces: Name Child-interface Status fab0 fe-0/0/5 Up fab0 fab1 fe-2/0/5 Up fab1 Redundant-ethernet Information: Name Status Redundancy-group reth0 Up 2 reth1 Up 1 Interface Monitoring: Interface Weight Status Redundancy-group fe-0/0/3 128 Down 1 <-- fe-2/0/3 128 Up 1 fe-2/0/2 128 Up 1 fe-0/0/2 128 Up 1
In the above situation, if ip-monitoring fails for a global-weight of 210 or less than 255, the failure can still cause a failover, as shown below:
{primary:node0}[edit] root@primarynode# run show chassis cluster status Cluster ID: 10 Node Priority Status Preempt Manual failover Redundancy group: 0 , Failover count: 0 node0 200 primary no no node1 10 secondary no no Redundancy group: 1 , Failover count: 1 node0 0 secondary yes no <-- Because of IP and interface-monitor failure on node0 for RG1, threshold=0 node1 is primary. node1 10 primary yes no <-- The priority for node1 did not change to zero because threshold=45 for node1. The outputs below show {primary:node0}[edit] root@primarynode# run show chassis cluster information detail node0: -------------------------------------------------------------------------- Redundancy mode: Configured mode: active-active Operational mode: active-active Redundancy group: 0, Threshold: 255, Monitoring failures: none Events: Sep 13 15:56:04.223 : hold->secondary, reason: Hold timer expired Sep 13 15:56:59.408 : secondary->primary, reason: Control & Fabric links down Redundancy group: 1, Threshold: -83, Monitoring failures: interface-monitoring, ip-monitoring <-- Threshold is 127-210 = -83. Events: Sep 13 17:15:42.274 : secondary-hold->secondary, reason: Back to back failover interval Sep 13 17:17:54.614 : secondary->primary, reason: Remote node is in secondary hol Sep 13 17:39:05.064 : primary->secondary-hold, reason: Monitor failed: IF IP Sep 13 17:39:06.076 : secondary-hold->secondary, reason: Back to back failover interval
Note: The example below clarifies the logical interface status when the link is down with and without interface-monitoring enabled for child links.
Without the interface-monitoring configuration: If child links in a reth on a node go down, the reth interface will go down too, as shown below:
{primary:node0}[edit] root@primarynode# run show chassis cluster interfaces Control link status: Up Control interfaces: Index Interface Status 0 fxp1 Up Fabric link status: Up Fabric interfaces: Name Child-interface Status fab0 fe-0/0/5 Up fab0 fab1 fe-2/0/5 Up fab1 Redundant-ethernet Information: Name Status Redundancy-group reth0 Up 2 reth1 Down 1 <--reth is down and reth1 on Node0 continues being used, but the chassis cluster status does not change.
The priority will stay at configured values:
{primary:node0}[edit] root@primarynode# run show chassis cluster status Cluster ID: 10 Node Priority Status Preempt Manual failover Redundancy group: 0 , Failover count: 0 node0 200 primary no no node1 10 secondary no no Redundancy group: 1 , Failover count: 2 node0 200 primary yes no node1 10 secondary yes no
With interface-monitoring enabled:
{primary:node0}[edit] root@primarynode# run show chassis cluster status Cluster ID: 10 Node Priority Status Preempt Manual failover Redundancy group: 0 , Failover count: 1 node0 200 primary no no node1 10 secondary no no Redundancy group: 1 , Failover count: 2 node0 0 secondary yes no node1 10 primary yes no <-- Failover is triggered for the corresponding RG.
{primary:node0}[edit] root@primarynode# run show chassis cluster interfaces Control link status: Up Control interfaces: Index Interface Status 0 fxp1 Up Fabric link status: Up Fabric interfaces: Name Child-interface Status fab0 fe-0/0/5 Up fab0 fab1 fe-2/0/5 Up fab1 Redundant-ethernet Information: Name Status Redundancy-group reth0 Up 2 reth1 Up 1 <-- reth1 is up because the child links of reth1 on node1 are now being used. Interface Monitoring: Interface Weight Status Redundancy-group fe-0/0/3 128 Down 1 <-- Child links are down. fe-2/0/3 128 Up 1 fe-2/0/2 128 Up 1 fe-0/0/2 128 Down 1 <-- Child links are down.