After downgrading SRX210BE, SRX210HE and SRX210HE-POE  the SRX may report being a SRX-650 and unable to initialize on-board interfaces.  (SRX210B, SRX210H & SRX210H-POE units are not impacted)

Symptoms

Upon downgrade to Junos versions below 11.1 the BE and HE versions of SRX210 will bootup however it will report as a SRX-650 model, and will be unable to setup the on-board interfaces.

root@SRX-210HE> show version
Model: srx650   <----Incorrect Model
JUNOS Software Release [10.4R1.9]


root@SRX-210HE> show chassis hardware   
Hardware inventory:
Item             Version  Part number  Serial number     Description
Chassis
Midplane                                                             
System IO                            <----No Outputs seen
Routing Engine
FPC 0


root@SRX-210HE> show interfaces terse
Interface               Admin Link Proto    Local                 Remote
                                                                   <-----No listing of on-board interfaces
fxp2                    up    down
fxp2.0                  up    down tnp      0x1
gre                     up    up
ipip                    up    up
lo0                     up    up
lo0.16384               up    up   inet     127.0.0.1           --> 0/0
lo0.16385               up    up   inet     10.0.0.1            --> 0/0
                                            10.0.0.16           --> 0/0
                                            128.0.0.1           --> 0/0
                                            128.0.1.16          --> 0/0
lo0.32768               up    up
lsi                     up    up
mtun                    up    up
pimd                    up    up
pime                    up    up
pp0                     up    up
ppd0                    up    up
ppe0                    up    up
st0                     up    up
tap                     up    up
vlan                    up    down
   

Solution

SRX-210BE and SRX210HE units were introduced as of Junos 11.1.
Using versions prior to 11.1 is not supported on BE and HE versions of the SRX210 and may cause undesired results if used.

New Features in Junos OS Release 11.1 for SRX Series Services Gateways and J Series Services Routers

Reinstall Junos using USB to Junos 11.1 or higher using USB using below directions.
 
    Install Software via CLI (Method 3 - from Junos software copied to USB stick)



Please refer to  JTAC Recommended Junos Software Versions for current recommended Junos versions