After downgrading SRX210BE, SRX210HE and SRX210HE-POE the SRX may report being a SRX-650 and unable to initialize on-board interfaces. (SRX210B, SRX210H & SRX210H-POE units are not impacted)
Upon downgrade to Junos versions below 11.1 the BE and HE versions of SRX210 will bootup however it will report as a SRX-650 model, and will be unable to setup the on-board interfaces.
root@SRX-210HE> show version Model: srx650 <----Incorrect Model JUNOS Software Release [10.4R1.9] root@SRX-210HE> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis Midplane System IO <----No Outputs seen Routing Engine FPC 0 root@SRX-210HE> show interfaces terse Interface Admin Link Proto Local Remote <-----No listing of on-board interfaces fxp2 up down fxp2.0 up down tnp 0x1 gre up up ipip up up lo0 up up lo0.16384 up up inet 127.0.0.1 --> 0/0 lo0.16385 up up inet 10.0.0.1 --> 0/0 10.0.0.16 --> 0/0 128.0.0.1 --> 0/0 128.0.1.16 --> 0/0 lo0.32768 up up lsi up up mtun up up pimd up up pime up up pp0 up up ppd0 up up ppe0 up up st0 up up tap up up vlan up down
SRX-210BE and SRX210HE units were introduced as of Junos 11.1. Using versions prior to 11.1 is not supported on BE and HE versions of the SRX210 and may cause undesired results if used. New Features in Junos OS Release 11.1 for SRX Series Services Gateways and J Series Services Routers
Reinstall Junos using USB to Junos 11.1 or higher using USB using below directions. Install Software via CLI (Method 3 - from Junos software copied to USB stick) Please refer to JTAC Recommended Junos Software Versions for current recommended Junos versions