This article describes the issue of the increase in the Output packet error count for the fabric link, when a SRX 1000/3000/5000 cluster operates in the Z mode.
When a SRX 1000/3000/5000 cluster operates in the Z mode, the output packet error count increases for the fabric link.
The output of show interfaces extensive for the fabric link shows that the Output packet error count increases over time. This can be observed on SRX 1000/3000/5000 clusters that operate in the Z mode. In Z-mode, the traffic traverses through the fabric link and this error count also increases with the traffic flowing through. Here is a sample output of when the device is in this condition:
Filter statistics: Input packet count 5802585972 Input packet rejects 1544 Input DA rejects 0 Input SA rejects 0 Output packet count 4553569332 Output packet pad count 0 Output packet error count 965116 < CAM destination filters: 0, CAM source filters: 0