This article provides information on the various types of error fields which appear in the output of the show interface ge-0/0/0 extensive command.
The following highlighted truncated output of the command indicates a few error fields; the meaning of which is unknown to many users.
user@srx>show interface extensive
Physical interface: ge-0/0/0, Enabled, Physical link is Up Interface index: 134, SNMP ifIndex: 505, Generation: 137 Link-level type: Ethernet, MTU: 1514, Link-mode: Full-duplex, Speed: 1000mbps, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Enabled, Auto-negotiation: Enabled, Remote fault: Online Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Link flags : None CoS queues : 8 supported, 8 maximum usable queues Hold-times : Up 0 ms, Down 0 ms Current address: 00:26:88:eb:62:c0, Hardware address: 00:26:88:eb:62:c0 Last flapped : 2012-06-04 14:39:14 UTC (00:35:10 ago) Statistics last cleared: Never Traffic statistics: Input bytes : 30972 0 bps Output bytes : 0 0 bps Input packets: 427 0 pps Output packets: 0 0 pps Input errors: Errors: 0, Drops: 0, Framing errors: 0, Runts: 0, Policed discards: 0, L3 incompletes: 0, L2 channel errors: 0, L2 mismatch timeouts: 0, FIFO errors: 0, Resource errors: 0 Output errors: Carrier transitions: 1, Errors: 0, Drops: 0, Collisions: 0, Aged packets: 0, FIFO errors: 0, HS link CRC errors: 0, MTU errors: 0, Resource errors: 0
The errors can be classified as Input and Output . Input errors account for the erroneous counters, which occur at the input queue of SRX/MX interface.
Output errors can be broadly summarized as follows:
Carrier transitions : Number of times that the interface has gone from down to up. This number does not normally increment quickly; increasing only when the cable is unplugged, the far-end system is powered down and then up, or another issue occurs. If the number of carrier transitions increments quickly (perhaps once every 10 seconds), the cable, far-end system, PIC (Physical Interface Cards) or PIM (Physical Interface Module) is malfunctioning.
Errors : Sum of the outgoing frame aborts and FCS errors.
Drops : The number of packets which are dropped by the output queue of the I/O Manager ASIC. If the interface is saturated, this number increments once for every packet, which is dropped by the ASIC's RED mechanism.
Collisions : The number of Ethernet collisions. The Gigabit Ethernet PIC supports only full-duplex operation; so for Gigabit Ethernet PICs, this number should always remain 0. If it is non-zero, there is a software bug.
Aged packets : The number of packets which remained in the shared packet SDRAM for so long, that the system automatically purged them. The value in this field should never increment. If it does, it is most likely a software bug or possible malfunctioning hardware.
FIFO errors : The number of FIFO errors in the send direction, as reported by the ASIC on the PIC. If this value is ever non-zero, the PIC is probably malfunctioning.
HS link CRC errors : The number of errors on the high-speed links between the ASICs, which are responsible for handling the router interfaces.
MTU errors : The number of packets whose size exceeded the interface MTU.
Resource errors : Sum of transmit drops.