Description

This article provides a sample configuration to enable Change and Configuration Management (CCM) tools on EX switches.

Symptoms


Solution


Topology:

alt
Control vlan 100

Configuration to enable CCM between DUT1 port 0/0/1 to DUT2 port 0/0/2:

DUT1 OAM config:

set protocols oam ethernet connectivity-fault-management action-profile ERPtest event adjacency-loss
set protocols oam ethernet connectivity-fault-management action-profile ERPtest action interface-down
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA level 3
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA name-format character-string
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA maintenance-association MDAs continuity-check interval 10ms
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA maintenance-association MDAs continuity-check loss-threshold 3
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA maintenance-association MDAs mep 5 interface ge-0/0/1.0
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA maintenance-association MDAs mep 5 interface vlan-id 100
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA maintenance-association MDAs mep 5 auto-discovery
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA maintenance-association MDAs mep 5 remote-mep 6 action-profile ERPtest

DUT2 OAM config:

set protocols oam ethernet connectivity-fault-management action-profile ERPtest event adjacency-loss
set protocols oam ethernet connectivity-fault-management action-profile ERPtest action interface-down
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA level 3
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA name-format character-string
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA maintenance-association MDAs continuity-check interval 10ms
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA maintenance-association MDAs continuity-check loss-threshold 3
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA maintenance-association MDAs mep 6 interface ge-0/0/2.0
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA maintenance-association MDAs mep 6 interface vlan-id 100
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA maintenance-association MDAs mep 6 auto-discovery
set protocols oam ethernet connectivity-fault-management maintenance-domain MDA maintenance-association MDAs mep 6 remote-mep 5 action-profile ERPtest