This article provides information on how to verify if the internal mapping of SRX3600 hardware is accurate and the device recognizes it properly. This article is also applicable for SRX3400 series devices. This article should be considered as a precursor to opening a JTAC ticket for reporting a possible hardware issue.
To verify if all the cards are properly inserted in the designated slots and the device is correctly recognizing all the cards.
Execute the following commands in the device's operational mode to find the internal mapping of NPC/IOC/SPC.
request pfe execute target tnp tnp-name node0.cpp0 command "show datapath all" | match "IOC slot" request pfe execute target tnp tnp-name node0.cpp0 command "show datapath all" | match "SPC slot" request pfe execute target tnp tnp-name node0.cpp0 command "show datapath all" | match "IOC slot" {primary:node0} root@FW-SRX-1> request pfe execute target tnp tnp-name node0.cpp0 command "show datapath all" | match "NPC slot" < For Node 0 GOT: NPC slot 10 (IOC Domain): GOT: NPC slot 10 (SPC Domain): GOT: NPC slot 12 (IOC Domain): GOT: NPC slot 12 (SPC Domain): {primary:node0} root@FW-SRX-1> request pfe execute target tnp tnp-name node1.cpp0 command "show datapath all" | match "NPC slot" < For Node 1 GOT: NPC slot 10 (IOC Domain): GOT: NPC slot 10 (SPC Domain): GOT: NPC slot 12 (IOC Domain): GOT: NPC slot 12 (SPC Domain): {primary:node0} root@FW-SRX-1> request pfe execute target tnp tnp-name node0.cpp0 command "show datapath all" | match "SPC slot" < For Node 0 GOT: SPC slot 7: GOT: SPC slot 8: GOT: SPC slot 9: GOT: SPC slot 11: {primary:node0} root@FW-SRX-1> request pfe execute target tnp tnp-name node1.cpp0 command "show datapath all" | match "SPC slot" < For Node 1 GOT: SPC slot 7: GOT: SPC slot 8: GOT: SPC slot 9: GOT: SPC slot 11: {primary:node0} root@FW-SRX-1> request pfe execute target tnp tnp-name node0.cpp0 command "show datapath all" | match "IOC slot" | except BCM565XX < For Node 0 OT: IOC slot 0: GOT: IOC slot 1: GOT: IOC slot 2: GOT: IOC slot 3: GOT: IOC slot 4: GOT: IOC slot 5: {primary:node0} root@FW-SRX-1> request pfe execute target tnp tnp-name node0.cpp0 command "show datapath all" | match "IOC slot" | except BCM565XX <----- For Node 1 GOT: IOC slot 0: GOT: IOC slot 1: GOT: IOC slot 2: GOT: IOC slot 3: GOT: IOC slot 4: GOT: IOC slot 5:
{primary:node0} root@FW-SRX-1> show chassis hardware | match NPC | except PIC < 2 NPCs in slot 10 and 12 for each node. FPC 10 REV 13 750-017866 AAAT2834 SRX3k NPC FPC 12 REV 12 750-017866 AAAD1583 SRX3k NPC FPC 10 REV 12 750-017866 AAAD1572 SRX3k NPC FPC 12 REV 14 750-017866 AABB4726 SRX3k NPC {primary:node0} root@FW-SRX-1> show chassis hardware | match SPC | except PIC FPC 7 REV 10 750-016077 VR7085 SRX3k SPC FPC 8 REV 11 750-016077 AAAH4918 SRX3k SPC FPC 9 REV 11 750-016077 AAAT8485 SRX3k SPC FPC 11 REV 11 750-016077 AAAH4915 SRX3k SPC FPC 7 REV 10 750-016077 AAAC3531 SRX3k SPC FPC 8 REV 11 750-016077 AAAT8505 SRX3k SPC FPC 9 REV 12 750-016077 AAAZ2922 SRX3k SPC FPC 11 REV 10 750-016077 AAAC3502 SRX3k SPC {primary:node0} root@FW-SRX-1> show chassis hardware | match SPC < 4 SPC’s in total in slot 7,8,9 and 11 for each node. FPC 7 REV 10 750-016077 VR7085 SRX3k SPC FPC 8 REV 11 750-016077 AAAH4918 SRX3k SPC FPC 9 REV 11 750-016077 AAAT8485 SRX3k SPC FPC 11 REV 11 750-016077 AAAH4915 SRX3k SPC FPC 7 REV 10 750-016077 AAAC3531 SRX3k SPC FPC 8 REV 11 750-016077 AAAT8505 SRX3k SPC FPC 9 REV 12 750-016077 AAAZ2922 SRX3k SPC FPC 11 REV 10 750-016077 AAAC3502 SRX3k SPC {primary:node0} root@FW-SRX-1> show chassis hardware | match GE | except PIC < 6 IOC’s in slot 0, 1,2,3,4 and 5 for each node. FPC 0 REV 11 750-021882 AAAD9754 SRX3k SFB 12GE FPC 1 REV 15 750-020321 AAAV8272 SRX3k 2x10GE XFP FPC 2 REV 20 750-020321 AAEE2737 SRX3k 2x10GE XFP FPC 3 REV 20 750-020321 AAEC6444 SRX3k 2x10GE XFP FPC 4 REV 12 750-020324 AAAE9290 SRX3k 16xGE TX FPC 5 REV 11 750-020317 VP3944 SRX3k 16xGE SFP FPC 0 REV 11 750-021882 AAAD9809 SRX3k SFB 12GE FPC 1 REV 13 750-020321 TV3688 SRX3k 2x10GE XFP FPC 2 REV 20 750-020321 AAEC6494 SRX3k 2x10GE XFP FPC 3 REV 20 750-020321 AAEE2738 SRX3k 2x10GE XFP FPC 4 REV 17 750-020324 AADN8356 SRX3k 16xGE TX FPC 5 REV 11 750-020317 AAAE9144 SRX3k 16xGE SFP
2021-09-20: Marked article as EOL/EOE. 2020-07-25: Archived article