This article describes the issue of being unable to disable the flow-control on a SRX branch or J-series device's interface.
When trying to configure the no-flow-control under edit interface > interface-name > gigether-options , the device does not show the option to configure:
[edit] admin@h1# run show version Hostname: SRX Model: srx210h JUNOS Software Release [11.2R1.10] [edit] admin@h1# set interfaces ge-0/0/0 gigether-options ?
> 802.3ad IEEE 802.3ad + apply-groups Groups from which to inherit configuration data + apply-groups-except Don't inherit configuration data from these groups > auto-negotiation Enable auto-negotiation ignore-l3-incompletes Ignore L3 incomplete errors loopback Enable loopback > mpls MPLS options no-auto-negotiation Disable auto-negotiation no-loopback Don't enable loopback > redundant-parent Parent of this interface
Currently, Ethernet flow control is not supported on J-series and SRX branch devices. As it is not supported and is by default disabled, disabling flow control via the edit interface > interface-name > gigether-options configuration is not possible. Note : Ethernet flow control is available on SRX high-end devices.