This article describes the issue of second control link failure on 3400/3600 SRX chassis cluster.
Dual Control Links are configured on 3000 SRX Series Chassis Cluster, with one CRM installed on each member. The second control link does not work.
Symptoms :
{primary:node0} root@SRX3400-1> show chassis cluster control-plane statistics Control link statistics: Control link 0: Heartbeat packets sent: 453055 Heartbeat packets received: 453053 Heartbeat packet errors: 0 Control link 1: Heartbeat packets sent: 453055 Heartbeat packets received: 0 Heartbeat packet errors: 0 Fabric link statistics: Probes sent: 453053 Probes received: 452789 Probe errors: 0 {secondary:node1} root@SRX3400-2> show chassis cluster control-plane statistics Control link statistics: Control link 0: Heartbeat packets sent: 899571 Heartbeat packets received: 899379 Heartbeat packet errors: 0 Control link 1: Heartbeat packets sent: 899571 Heartbeat packets received: 0 Heartbeat packet errors: 0 Fabric link statistics: Probes sent: 899569 Probes received: 898851 Probe errors: 0
If you are not using Juniper certified SFP modules on HA1 ports, please change them to Juniper certified.
Refer to the SRX3400 Services Gateway Hardware Guide (Chapter 12: Replacing Hardware Components on the SRX3400 Services Gateway).
A list of certified SFP modules.
2020-07-02: Article reviewed for accuracy; Minor changes added to highlight identifying problem state and link for certified SFP modules.