This article describes the Interface ge-0/0/7-9 behavior on the SRX1400 going down when connected to a switch.
The SRX1400 can come with 2 possible types of SYSIO cards. SRX1K-SYSIO-GE: 6 10/100/1000 RJ45 + 4 1000Base-X SFP + 2 1000Base-X SFP shared as data or clustering control SRX1K-SYSIO-XGE: 3 10GBase-X SFP plus + 6 10/100/1000 RJ45 + 1 1000Base-X SFP + 2 1000Base-X SFP shared as data or clustering control There are 2 distinct issues: 1. If the SYSIO card is SRX1K-SYSIO-GE Interface ge-0/0/6 can be up but ge-0/0/7-9 is down. Configurations are the same. This can happen mainly when the ports are connected to other vendors equipment
root@TMH_HDC_FW1> show configuration interfaces ge-0/0/7 root@TMH_HDC_FW1> show interfaces terse ge-0/0/7 Interface Admin Link Proto Local Remote ge-0/0/7 up down root@TMH_HDC_FW1> show interfaces ge-0/0/7 extensive --snipped-- Autonegotiation information: Negotiation status: Incomplete <--
2. If the SYSIO card is SRX1K-SYSIO-XGE Interfaces xe-0/0/7-9 support connections in both 10GE and 1GE modes. However when connecting the port to 1GE the link does not come up
Setup: SRX1400-2 xe-0/0/7 === ge-0/0/0 ( EX ) > show interfaces extensive xe-0/0/7 | find autone Autonegotiation information: Negotiation status: Incomplete --- INCOMPLETE
> show interfaces extensive xe-0/0/7 | find autone Autonegotiation information: Negotiation status: Incomplete --- INCOMPLETE