This article provides information on how to implement a chassis cluster on the SRX1400 device.
From Junos 11.1, High Availability is supported on SRX1400. This is different from the SRX3000 device, which has dedicated control port for the ge-0/0/10 and ge-0/0/11 control links that will be used as control ports, when the Chassis Cluster is enabled. The physical link status of the control ports is down, but the ports are connected back to back. Why are they down?
The Chassis Cluster control port 0 and port 1 can only be ge-0/0/10 and ge-0/0/11 , when the Chassis Cluster is enabled on a SRX1400 device. NOTE: When you use ge-0/0/11 as a control port, you must use a fiber SFP transceiver, but you can use copper or fiber SFP transceiver on ge-0/0/10. The other configuration instructions can be found in the TN10 Tech Note for high-end SRX devices. For more information, refer to KB15650 - SRX Getting Started - Configure Chassis Cluster (High Availability) [juniper.net] . Configuration for the Chassis Cluster:
{primary:node0}[edit] root@srx1400-1# show chassis cluster reth-count 2; redundancy-group 0 { node 0 priority 200; node 1 priority 100; } redundancy-group 1 { node 0 priority 200; node 1 priority 100; }
{primary:node0}[edit] root@SRX1400-1# run show chassis cluster information node0: -------------------------------------------------------------------------- Redundancy mode: Configured mode: active-active Operational mode: active-active Control link statistics: Control link 0: Heartbeat packets sent: 73138 Heartbeat packets received: 5905 Heartbeat packet errors: 0 Duplicate heartbeat packets received: 5685 Control link 1: Heartbeat packets sent: 73138 Heartbeat packets received: 9955 Heartbeat packet errors: 0 Duplicate heartbeat packets received: 93 Control recovery packet count: 0 Sequence number of last heartbeat packet sent: 73135 Sequence number of last heartbeat packet received: 5732 Fabric link statistics: Probes sent: 73135 Probes received: 6945 Probe errors: 0 Probes not processed: 6692 Probes dropped due to control link down: 0 Probes dropped due to fabric link down: 0 Sequence number of last probe sent: 73135 Sequence number of last probe received: 5732 Chassis cluster LED information: Current LED color: Green Last LED change reason: No failures
{primary:node0} root@SRX1400-a> show chassis cluster interfaces Control link 0 name: em0 Control link 1 name: em1 Control link status: Up Fabric interfaces: Name Child-interface Status fab0 ge-0/0/2 up fab0 fab1 ge-4/0/2 up fab1 Fabric link status: Up