The article helps to resolve a Chassis Cluster 'down' issue, due to the Control Link failing to come up.
This article is part of the Resolution Guide -- SRX Chassis Cluster (High Availability) .
Chassis Cluster is down due to the Control Link being down.
Run the following command to check if the Control Link is down:
Sample output:
For a Branch series SRX services gateway device:
{primary:node0}root@J-SRX> show chassis cluster interfaces Control link 0 name: fxp1
Control link status: Down
For a High End series SRX services gateway device:
{primary:node0}root@J-SRX> show chassis cluster interfaces Control link 0 name: em0Control link 1 name: em1
Perform the following steps to troubleshoot and correct a Control Link down:
Do you have a switch in between the two Chassis Cluster nodes for the Control Link?
Remove the switch and try a direct connection of the control ports. Now reboot the secondary node.
Is the interface link light GREEN for control link on both nodes?
Change the cable that you are using for control link. Is the interface link light GREEN now?
Is this device an SRX 5000 series service gateway device?
Once the correct ports are connected for the control link, if still seeing issue then proceed to Step 7.
Reconfigure the control link port to a different SPC, move the cable and reboot both nodes. Is the control link up?
If the Control Link is SFP-type port, change the transceiver on both ends. Ensure that the transceivers are same type (LX, SX, etc.) and that they are Juniper-branded parts. Is the Control Link up now?
Follow steps in KB21781 - [SRX] Data Collection Checklist - Logs/data to collect for troubleshooting [juniper.net] and open a case with your technical support representative.
Collect the following information for JTAC (collect from both nodes of the Chassis Cluster).
show chassis cluster status show chassis cluster statistics show chassis cluster information show log jsrpd show log messages show log chassisd request support information
2023-10-18: Minor Modification in the solution section.2020-09-29: Updated the link in step 5.