Description

QFX5100s continuously generates parity errors and SBUS transaction errors.

Symptoms

The following parity Errors and SBUS Transaction Errors logs appear constantly:

 

fpc0 Parity error..

fpc0 Error in: SBUS transaction.

fpc0 Unit 0: soc_ser_correction: mem write ING_FLEX_CTR_OFFSET_TABLE_4.ipipe0[33311] failed: Invalid parameter

fpc0 Parity error..

fpc0 Error in: SBUS transaction.

fpc0 Unit 0: soc_ser_correction: mem write ING_FLEX_CTR_OFFSET_TABLE_4.ipipe0[33919] failed: Invalid parameter

fpc0 _soc_mem_array_sbusdma_read: ING_FLEX_CTR_COUNTER_TABLE_5_Y.ipipe0 failed(ERR)

fpc0 H/W received sbus nack with error bit set.

 

The switch is running 14.1X53-D30, which is now end of support.

Solution

The issue is resolved through PR1161821

 

Upgrade your switch to a supported version to mitigate this issue.

 

NOTE: Rebooting the switch will resolve the issue but this is a temporarily workaround since might come back later.

Modification History

2026-08-06 : Article Created