Description

The AE interface has a single member and the TWAMP light service configured on 2 GNFs. These 2 GNF nodes has the services rpm twamp client session established, they had  PING_TEST_COMPLETED in the message log before addibg more AE bundle members.  After adding more AE members to the bundle,

Symptoms

Expected output on syslog is "PING_TEST_FAILED", but it shows "PING_TEST_COMPLETED" under this issue.

 

PING_TEST_COMPLETED changed t to PING_TEST_FAILED below:


 

labroot@MX2020-re0> show services rpm twamp client session 
Connection      Session         Sender           Sender Reflector        Reflector
Name            Name            address          port   address          port
__r__344        __r__345        10.222.11.77     59777 10.222.11.76       862

labroot@MX2020-re0> show log messages.0.gz |match __r__344 |find PING_TEST_FAILED |match ping
:
Jan  7 17:27:41.662  MX2020-1-re0 rmopd[29922]: PING_TEST_COMPLETED: pingCtlOwnerIndex = __r__344, pingCtlTestName = __r__345
Jan  7 17:27:52.675  MX2020-1-re0 rmopd[29922]: PING_PROBE_FAILED: pingCtlOwnerIndex = __r__344, pingCtlTestName = __r__345
Jan  7 17:27:55.683  MX2020-1-re0 rmopd[29922]: PING_TEST_FAILED: pingCtlOwnerIndex = __r__344, pingCtlTestName = __r__345
:
labroot@MX2020-re0> show services rpm twamp client probe-results |match "loss|Owner" 
    Owner: __r__344, Test: __r__345
      Probes sent: 3, Probes received: 3, Loss percentage: 0.000000
      Probes sent: 5, Probes received: 5, Loss percentage: 0.000000
      Probes sent: 154378, Probes received: 154375, Loss percentage: 0.001943

labroot@mx2010-re1> show services rpm twamp client session           
Connection      Session         Sender           Sender Reflector        Reflector
Name            Name            address          port   address          port
__r__346        __r__347        10.222.11.76     61787 10.222.11.77       862

labroot@mx2010-re1> show log messages |match ping |match __r__346 
:
Jan  7 17:26:03.619  mx2010-5-re1 rmopd[86417]: PING_TEST_COMPLETED: pingCtlOwnerIndex = __r__346, pingCtlTestName = __r__347

 

 

Solution

This is due to the public/external PR1471606

Resolved-In:

junos:20.3R3-S2 junos:21.2R3-S5 junos:21.3R3-S1 junos:21.4R2 junos:21.4R3-S4 junos:22.1R1

Modification History

2026-02-11 : Article Created