Device reports the following for FPC 3, indicating a thermal event followed by a BT power optimization notice:
>show chassis environment fpc 3 no-forwarding FPC 3 BT-1 Temp Sensor 0 OK 97 degrees C / 206 degrees F FPC 3 BT-1 Temp Sensor 1 OK 100 degrees C / 212 degrees F ==== >>>> hits threshold / may go higher FPC 3 BT-2 Temp Sensor 0 OK 61 degrees C / 141 degrees F FPC 3 BT-2 Temp Sensor 1 OK 61 degrees C / 141 degrees F
BT-1 sensors on FPC 3 recorded temperatures that hit threshold or may go higher, likely triggering thermal mitigation.
>show chassis environment fpc 3 no-forwarding
FPC 3 BT-1 Temp Sensor 0 OK 97 degrees C / 206 degrees F
FPC 3 BT-1 Temp Sensor 1 OK 100 degrees C / 212 degrees F ==== >>>> hits threshold / may go higher
FPC 3 BT-2 Temp Sensor 0 OK 61 degrees C / 141 degrees F
FPC 3 BT-2 Temp Sensor 1 OK 61 degrees C / 141 degrees F
A thermal mitigation response was initiated for BT Chip 1 on FPC 3.
Relevant log:
re0-hwdre: HWD_FPC_VOLT_POWER_OPTIMIZED_NOTICE: BT power optimized for Chip 1 Fru /Chassis[0]/Fpc[3]
Note: This log message is purely informational. It is not a consequence of any CMError and does not indicate a failure. Sometimes it may appear alongside other events, but there is no direct correlation.
Recommendations:
Recommended Commands:
> show chassis environment fpc 3
Checklist: