This article explains about alarm generated on Fan airflow direction mismatch even if the Airflow physically matches with the type of chassis
user@switch> show chassis alarms no-forwarding
2 alarms currently active
Alarm time Class Description
2024-11-16 10:29:57 UTC Major FPC 0 Fan & PSU Airflow direction mismatch
2024-11-16 10:29:57 UTC Major FPC 0 Fan Airflow direction mismatch
user@switch> show chassis hardware detail no-forwarding
Power Supply 0 REV 01 640-107107 xxxxxxxxxxx JPSU-550-C-AC-AFO
Power Supply 1 REV 01 640-107107 xxxxxxxxxxx JPSU-550-C-AC-AFO
Fan Tray 0 Fan Module, Airflow In (AFI) ----->>>> Air Inflow Direction
Fan Tray 1 Fan Module, Airflow Out (AFO)
Possible steps to clear that "Airflow mismatch" alarm:
By replacing the Fan tray , there were no alarms & chassis hardware output shows correct type of airflow direction on the FRU
Fan Tray 0 Fan Module, Airflow Out (AFO)