This article outlines how to resolve the issue of missing 'show chassis hardware' and 'show chassis fpc' outputs on a QFX switch following an upgrade.
1) Empty output under the command 'show chassis fpc' post the upgrade.
user@labroot>show chassis fpc
Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer
0 Empty
1 Empty
2 Empty
3 Empty
4 Empty
5 Empty
6 Empty
7 Empty
8 Empty
9 Empty
2) No inventory listed under 'show chassis hardware' except the chassis.
user@labroot>show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis xxxxxxxxxxx QFX5110-xx
Power-cycle of the switch should resolve the problem. In instances were power-cycle does not fix the issue, need to go for chassis replacement.
Note: Although console logs don't always show the exact cause of an issue, it's important to examine them for any potential indicators.