Description

Switch log indicate framing errors, runts and CRC errors on an 100g interface.


> Framing errors occur when received Ethernet frames have incorrect or corrupted frame structures.

> Runts are frames smaller than 64 bytes that failed CRC checks and were discarded.



Solution

Please try the following steps:

 

1. Check the duplex and speed settings on both ends of the link. Ensure they are identical (100G full-duplex in this case).

2. Clean or replace the fibre or optics. Dirty or damaged optics are common at high speeds (100G). Try replacing the fibre cable or optic module.

Modification History

2025-07-07 : Article Created