Switch log indicate framing errors, runts and CRC errors on an 100g interface.
> Framing errors occur when received Ethernet frames have incorrect or corrupted frame structures.
> Runts are frames smaller than 64 bytes that failed CRC checks and were discarded.
Please try the following steps:
1. Check the duplex and speed settings on both ends of the link. Ensure they are identical (100G full-duplex in this case).
2. Clean or replace the fibre or optics. Dirty or damaged optics are common at high speeds (100G). Try replacing the fibre cable or optic module.