This issue affects Junos OS Evolved 23.2R2-EVO and 23.4R1-EVO.
Medium
CVSS 3.1: 6.6 (CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H)
CVSS 4.0: 7.0 (CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N)

Problem

An Improper Physical Access Control vulnerability in the console port control of Juniper Networks Junos OS Evolved allows an attacker with physical access to the device to get access to a user account.

When the console cable is disconnected, the logged in user is not logged out. This allows a malicious attacker with physical access to the console to resume a previous session and possibly gain administrative privileges.

This issue affects Junos OS Evolved:
  • from 23.2R2-EVO before 23.2R2-S1-EVO, 
  • from 23.4R1-EVO before 23.4R2-EVO.

Juniper SIRT is not aware of any malicious exploitation of this vulnerability.

This issue was found during internal product security testing or research.

Solution

The following software releases have been updated to resolve this specific issue: 23.2R2-S1-EVO, 23.4R2-EVO, 24.2R1-EVO, and all subsequent releases.

This issue is being tracked as 1802653 which is visible on the Customer Support website.

Note: Juniper SIRT's policy is not to evaluate releases which are beyond End of Engineering (EOE) or End of Life (EOL).

Workaround

There are no known workarounds for this issue.

It is recommended to limit physical access to the device to trusted administrators and users only.

Severity Assessment