An Improper Neutralization of Equivalent Special Elements vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on PTX Series allows a unauthenticated, adjacent attacker to cause a Denial of Service (DoS).
When MPLS packets are meant to be sent to a flexible tunnel interface (FTI) and if the FTI tunnel is down, these will hit the reject NH, due to which the packets get sent to the CPU and cause a host path wedge condition. This will cause the FPC to hang and requires a manual restart to recover.
Please note that this issue specifically affects PTX1000, PTX3000, PTX5000 with FPC3, PTX10002-60C, and PTX10008/16 with LC110x. Other PTX Series devices and Line Cards (LC) are not affected.
The following log message can be seen when the issue occurs:
Cmerror Op Set: Host Loopback: HOST LOOPBACK WEDGE DETECTED IN PATH ID <id> (URI: /fpc/<fpc>/pfe/<pfe>/cm/<cm>/Host_Loopback/<cm>/HOST_LOOPBACK_MAKE_CMERROR_ID[<id>])
This issue affects Juniper Networks Junos OS:
To be exposed to this issue FTI need to be configured:
[ interfaces fti0 unit <unit> tunnel ... ]
Juniper SIRT is not aware of any malicious exploitation of this vulnerability.
This issue was seen during production usage.
This issue has been assigned CVE-2024-21600.
The following software releases have been updated to resolve this specific issue: 20.4R3-S8, 21.1R3-S4, 21.2R3-S6, 21.3R3-S3, 21.4R3-S5, 22.1R2-S2, 22.1R3, 22.2R2-S1, 22.2R3, 22.3R1, and all subsequent releases.This issue is being tracked as PR 1653316 which is visible on the Customer Support website.Note: Juniper SIRT's policy is not to evaluate releases which are beyond End of Engineering (EOE) or End of Life (EOL).
The issue can be prevented by configuring a limit for reject packets via:
[ system ddos-protection protocols reject aggregate bandwidth 20 ]
2024-01-10: Initial Publication