Improper Handling of Exceptional Conditions in Ethernet interface frame processing of Juniper Networks Junos OS allows an attacker to send specially crafted frames over the local Ethernet segment, causing the interface to go into a down state, resulting in a Denial of Service (DoS) condition. The interface does not recover on its own and the FPC must be reset manually. Continued receipt and processing of these frames will create a sustained Denial of Service (DoS) condition.
This issue is platform-specific and affects the following platforms and line cards:
No other products or platforms are affected by this vulnerability.
An indication of this issue occurring can be seen in the system log messages, as shown below:
user@host> show log messages | match "Failed to complete DFE tuning"
fpc4 smic_phy_dfe_tuning_state: et-4/1/6 - Failed to complete DFE tuning (count 3)
and interface will be in a permanently down state:
user@host> show interfaces et-4/1/6 terse
Interface Admin Link Proto Local Remote
et-4/1/6 up down
et-4/1/6.0 up down aenet --> ae101.0
This issue affects Juniper Networks Junos OS:
This issue does not affect Juniper Networks Junos OS versions prior to 16.1R1.
Juniper SIRT is not aware of any malicious exploitation of this vulnerability.
This issue was seen during production usage.
This issue has been assigned CVE-2021-0290 .
The following software releases have been updated to resolve this specific issue: Junos OS 16.1R7-S7, 17.2R3-S3, 17.3R3-S8, 17.4R2-S11, 17.4R3-S1, 17.4R3-S5, 18.1R3-S10, 18.2R3-S3, 18.2R3-S8, 18.3R3-S1, 18.4R2-S3, 18.4R3, 19.1R2-S1, 19.1R3, 19.2R1-S3, 19.2R2, 19.3R2, 19.4R1, and all subsequent releases.
This issue is being tracked as 1463015 .
Software releases or updates are available for download at https://support.juniper.net/support/downloads/
2021-07-14: Initial Publication.