Due to an improper check for unusual or exceptional conditions in Juniper Networks Junos OS and Junos OS Evolved the Routing Protocol Daemon (RPD) service, upon receipt of a specific matching BGP packet meeting a specific term in the flowspec configuration, crashes and restarts causing a Denial of Service (DoS). Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition.
This issue affects only Multiprotocol BGP (MP-BGP) VPNv6 FlowSpec deployments.
This issue affects:
Juniper Networks Junos OS:
Juniper Networks Junos OS Evolved:
This issue does not affect:
Juniper Networks Junos OS versions prior to 18.4R1.
Juniper Networks Junos OS Evolved versions prior to 18.4R1-EVO.
The examples of the config stanza affected by this issue:
[ protocols bgp group <group-name> family inet6-vpn flow ]
Juniper SIRT is not aware of any malicious exploitation of this vulnerability.
This issue was found during internal product security testing or research.
This issue has been assigned CVE-2021-0236 .
The following software releases have been updated to resolve this specific issue:
Junos OS: 18.4R1-S8, 18.4R2-S7, 18.4R3-S7, 19.1R2-S2, 19.1R3-S4, 19.2R1-S6, 19.2R3-S2, 19.3R3-S2, 19.4R2-S4, 19.4R3-S1, 20.1R2, 20.1R3, 20.2R2, 20.2R3, 20.3R1-S1, 20.3R2, 20.4R1 and all subsequent releases.
Junos OS Evolved: 20.3R2-EVO, 20.4R1-EVO, and all subsequent releases.
This issue is being tracked as 1537085 .
Software releases or updates are available for download at https://support.juniper.net/support/downloads/
Do not configure "family inet6-vpn flow" under BGP if no inet6-vpn routes are required to be received.
2021-04-14: Initial Publication.