A high rate of VLAN authentication attempts sent from an adjacent host on the local broadcast domain can trigger high memory utilization by the BBE subscriber management daemon (bbe-smgd), and lead to a denial of service condition. The issue was caused by attempting to process an unbounded number of pending VLAN authentication requests, leading to excessive memory allocation. This issue only affects devices configured for DHCPv4/v6 over AE auto-sensed VLANs, utilized in Broadband Edge (BBE) deployments. Other configurations are unaffected by this issue. Affected releases are Juniper Networks Junos OS:
Juniper SIRT is not aware of any malicious exploitation of this vulnerability. This issue was seen in a production network. This issue has been assigned CVE-2018-0006 .
The following software releases have been updated to resolve this specific issue: 15.1R6-S2, 15.1R7, 16.1R5-S1, 16.1R6, 16.2R2-S2, 16.2R3, 17.1R2-S5*, 17.1R3*, 17.2R2, 17.3R1, 17.4R1, and all subsequent releases. *pending release This issue is being tracked as PRs 1284213 and 1268129 which are visible on the Customer Support website. Note: Juniper SIRT's policy is not to evaluate releases which are beyond End of Engineering (EOE) or End of Life (EOL).
Software Releases, patches and updates are available at https://www.juniper.net/support/downloads/ .
Since this issue is specific to auto-sense or dynamic VLANs, utilizing a static VLAN model will mitigate this issue.
2018-01-10: Initial publication