Receipt of a specifically malformed ICMP packet sent to the interface or loopback IP address of an E Series router while DEBUG severity icmpTraffic logging is enabled may lead to an SRP reset, type: processor exception 0x300 (data access), in task: ip_RxData_8. In a redundant SRP configuration, the system will recover immediately. However, additional malformed packets may cause follow-on SRP resets and lead to an extended service outage. The issue occurs when JunosE tries to convert the contents of the specifically malformed ICMP packet into human-readable text. Logging severities below DEBUG will not trigger the SRP reset. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. No other Juniper Networks products or platforms are affected by this issue. This issue has been assigned CVE-2014-6377 .
JunosE releases containing the fix specifically include: 13.3.3p0-1, 14.3.1p0-0-1, 14.3.2, 15.1.0, and all subsequent releases. This issue is being tracked as CQ 97568 and is visible on the Customer Support website. KB16765 [juniper.net] - "In which releases are vulnerabilities fixed?" describes which release vulnerabilities are fixed as per our End of Engineering and End of Life support policies.